| MODEL |
S5Q-PA |
S8Q-PA |
| FLOW RATES (@ 95% UVT) |
|
|
| US Public Health (16 mJ/cm2 ) |
11 GPM (42 lpm) (2.5 m3 /hr) |
19 GPM (72 lpm) (4.3 m3 /hr) |
| VIQUA Standard (30 mJ/cm2 ) |
6 GPM (23 lpm) (1.4 m3 /hr) |
10 GPM (38 lpm) (2.3 m3 /hr) |
| NSF/EPA (40 mJ/cm2 ) |
4.5 GPM (17 lpm) (1.0 m3 /hr) |
8 GPM (29 lpm) (1.8 m3 /hr) |
| DIMENSIONS |
|
|
| Chamber |
22” x 2.5” (56.1 cm x 6.5 cm) |
35.5” x 2.5” (90.4 cm x 6.5 cm) |
| Controller |
7.25” x 3.25” x 2.5” (18.6 cm x 8.1 cm x 6.4 cm) |
7.25” x 3.25” x 2.5” (18.6 cm x 8.1 cm x 6.4 cm) |
| Inlet/Outlet Port Size |
3/4” MNPT* |
3/4” MNPT* |
| Shipping Weight |
8 lbs (3.6 kg) |
11 lbs (5 kg) |
| ELECTRICAL |
|
|
| Voltage Hz |
100-240V / 50/60 |
100-240V / 50/60 Hz |
| Power Consumption |
30 W |
46 W |
| Maximum Operating Pressure |
125 psi (8.62 bar) |
125 psi (8.62 bar) |
| Influent Water Temperature |
2-40°C (36-104°F) |
2-40°C (36-104°F) |
| FEATURES |
|
|
| Visual “Power On” |
YES |
YES |
| Chamber Material |
304 SS |
304 SS |
| Visual Lamp Life Remaining |
YES |
YES |
| Audible Lamp Life Failure |
YES |
YES |
| Audible Lamp Replacement Reminder |
YES |
YES |
| UV Sensor |
NO |
NO |
| * /2B - BSP |
|
|
| |
S463RL – UV lamp for S5Q-PA |
S810RL – UV lamp for S8Q-PA |
| |
QS-463 – quartz sleeve for S5Q-PA |
QS-810 – quartz sleeve for S8Q-PA |
| |
BA-ICE-S – electronic ICE controller for |
BA-ICE-S – electronic ICE controller |